Site Requirements 
This section describes requirements for the site in which the DAS3 Series system is to be installed. 
Before you install the DAS3 Series system, ensure that all the criteria in this section are met. The 
section describes the following: 
 
Environmental Requirements 
Power 
Cabling 
Rack Mounting 
 
Environmental Requirements 
To have proper operation of the DAS3 Series system depends on a proper environment. This section 
describes environmental requirements for the site in which you intend to install the DAS3 Series 
system. 
 
Temperature Humidity and Altitude 
The system can tolerate a wide range of temperatures. Table 3-1 shows the recommendation for 
temperature, humidity, and altitude conditions in a central office (CO) environment. 
 
Table 3-1 
CO Operating Environment Requirements 
Environmental Specifications 
Descriptions 
Temperature 
-40º to 65ºC – Operating 
-40º to 70ºC – Storage 
Humidity 
5 to 95% (non condensing) 
Altitude 
0 to 10,000 ft (0 to 3048 m) 
 
 
To prevent the system from overheating, do not operate it in an area that exceeds the maximum 
recommended ambient temperature of 45ºC. 
 
Ventilation 
The DAS3 Series fans maintain a suitable operating temperature for the internal circuitry. Ensure that 
the air intake vents at the left side of the box and the air exhaust vents on the right side of the box are 
not obstructed in anyway. 
 