Canon Océ VarioPrint 6000+ Series Manual

Page of 119
Operator Manual
 
Page 79
5
 .
4  Glue tank
5.4.1  Setting the glue temperature:
By default, the gluing temperature is set to 155°C. A technician is able to change the 
gluing temperature by default according to the used glue (from 130°C to 180°C).
However, the operator has the option of adjusting the gluing temperature of ± 15°C using 
the 
 icon (see chapter 
The operator must also press the 
 icon at the bottom of the UI screen for the glue to 
reach the required gluing temperature.
Adjust to 170°C for glue Planatol HM9925 or 150°C for glue Relimelt F1.
5.4.2  Glue level in the tank:
Note: The glue level in the tank is checked when the glue has reached the required 
temperature and the cylinders are rotating.
If the glue level is too low, a warning message appears on the screen to inform the user 
that there is not enough glue in the tank. The operator must refill the tank with glue 
granules. For further details, see chapter 
If the glue level is higher than the "MAXI" level, a warning message appears on the 
screen. The operator must remove the surplus glue from the tank through the emptying 
valve. For further details, see chapter 
5.4.3  Safety shut-off in the event of glue overheating:
In accordance with international regulations, the glue tank is equipped with a temperature 
checking system. This device shuts down the machine if the sensor detects a glue 
temperature in excess of 190°C. 
The device included in the BB3002 binder requires the use of a glue whose application 
temperature is less than 165°C. If the protection system is triggered, the machine will shut 
down and an error message will be displayed on the screen. The machine can only be 
restarted by a qualified technician.