3  Emptying and refilling the glue tank
When the glue starts to oxidise (turning brown), the contents of the tank must be replaced. 
There is a draining valve under the tank for this purpose.
Preliminaries:
•  The glue must be at the right temperature (depending of glue) and the cylinders must 
be rotating.
• First empty the tank, and then refill it.
Emptying:
•  Raise the top panel and open the door on the front. When you do this, 
the cylinders 
stop turning!
• Place an aluminium container below the tank valve (CPB ref.: 9199883).
•  Open the valve as far as it will go using the spanner designed for the purpose 
 
(CPB ref.: 9403843). The glue will flow into the container.
• If the glue does not flow freely, use a fine rod to unblock the valve.
•  When the tank is almost empty, add a few glue granules to the tank to empty the rest of 
the used glue.
• When the tank is empty, close the valve and refill the tank. 
WARNING: 
To avoid any risk of burns, wait till the aluminium container has cooled down 
completely before removing it.