Filling:
• Close the valve using the key designed for the purpose (CPB ref.: 9403843).
•
Fill the tank (via both filling areas).
WARNING:
When the glue has completely melted, the level should always be between
the maximum and minimum levels.
• When the glue level is correct and the glue has totally melted, close the top panel and
restart the binder by pressing the green button on the loading console.
• The green indicator will light up as soon as the glue has reached the gluing temperature.
The binder is then ready for use.
Note: The minimum and maximum levels are indicated by notches in the scrapers inside
the tank.
max level
min level
Glue Type
CP Bourg Ref
PLANATOL HM
9925
9195046
20
Kg
RELIMELT F
1
5005666
25
Kg
COOLBIND
3730
9195035
20