Canon Océ VarioPrint 6000+ Series Manual

Page of 119
Operator Manual
 
Page 89
Filling:
• Close the valve using the key designed for the purpose (CPB ref.: 9403843).
•  
Fill the tank (via both filling areas).
WARNING: 
When the glue has completely melted, the level should always be between 
the maximum and minimum levels.
•  When the glue level is correct and the glue has totally melted, close the top panel and 
restart the binder by pressing the green button on the loading console. 
•  The green indicator will light up as soon as the glue has reached the gluing temperature. 
The binder is then ready for use.
Note: The minimum and maximum levels are indicated by notches in the scrapers inside 
the tank.
max level
min level
Glue Type
CP Bourg Ref
PLANATOL HM
9925
9195046
20
 Kg
RELIMELT F
1
5005666
25
 Kg
COOLBIND 
3730
9195035
20
 Kg