no sflow receiver
Use this command to set the sFlow collector parameters back to the defaults.
sflow receiver owner timeout
Use this command to configure a receiver as a timeout entry. As the sFlow receiver is 
configured as a timeout entry, information related to sampler and pollers are also shown in 
the running-config and are retained after reboot.
If a receiver is configured with a specific value, these configurations are not shown in the 
running-config
 file. Samplers and pollers information related to this receiver are also not 
shown in the running-config file.
Parameter
Description
Receiver Owner
The identity string for the receiver, the entity making use of this sFlowRcvrTable entry. The range is 
127 characters. The default is a null string. The empty string indicates that the entry is currently 
unclaimed and the receiver configuration is reset to the default values. An entity wishing to claim an 
sFlowRcvrTable entry must ensure that the entry is unclaimed before trying to claim it. The entry is 
claimed by setting the owner string to a non-null value. The entry must be claimed before assigning 
a receiver to a sampler or poller.
Receiver Timeout
The time, in seconds, remaining before the sampler or poller is released and stops sending samples 
to receiver. A management entity wanting to maintain control of the sampler is responsible for setting 
a new value before the old one expires. The allowed range is 0-2147483647 seconds. The default is 
zero (0).
No Timeout 
 
The configured entry will be in the config until you explicitly removes the entry.
Receiver Max 
Datagram Size
The maximum number of data bytes that can be sent in a single sample datagram. The 
management entity should set this value to avoid fragmentation of the sFlow datagrams. The 
allowed range is 200 to 9116). The default is 1400.
Receiver IP
The sFlow receiver IP address. If set to 0.0.0.0, no sFlow datagrams will be sent. The default is 
0.0.0.0.
Receiver Port
The destination Layer4 UDP port for sFlow datagrams. The range is 1-65535. The default is 6343.
Format
no sflow receiver rcvr_idx [owner | maxdatagram | ip | port]
Mode
Global Config
Format
sflow receiver index owner owner-string timeout
Mode