sflow receiver owner notimeout
Use this command to configure a receiver as a non-timeout entry. Unlike entries configured 
with a specific timeout value, this command will be shown in show running-config and 
retained after reboot. As the sFlow receiver is configured as a non-timeout entry, information 
related to sampler and pollers will also be shown in the running-config and will be retained 
after reboot.
If a receiver is configured with a specific value, these configurations are not shown in the 
running-config
 file. Samplers and pollers information related to this receiver are also not 
shown in the running-config file.
sflow sampler
A data source configured to collect flow samples is called a poller. Use this command to 
configure a new sFlow sampler instance on an interface or range of interfaces for this data 
source if rcvr_indx is valid.
Field
Description
index
Receiver index identifier. The range is 1 to 8.
Receiver Owner
The owner name corresponds to the receiver name. The identity string for the receiver, the entity 
making use of this sFlowRcvrTable entry. The range is 127 characters. The default is a null string. 
The empty string indicates that the entry is currently unclaimed and the receiver configuration is 
reset to the default values. An entity wishing to claim an sFlowRcvrTable entry must ensure that the 
entry is unclaimed before trying to claim it. The entry is claimed by setting the owner string to a 
non-null value. The entry must be claimed before assigning a receiver to a sampler or poller.
Format
sflow receiver index owner owner-string notimeout
Mode
Global Config
Field
Description
index
Receiver index identifier. The range is 1 to 8.
Receiver Owner
The owner name corresponds to the receiver name. The identity string for the receiver, the entity 
making use of this sFlowRcvrTable entry. The range is 127 characters. The default is a null string. 
The empty string indicates that the entry is currently unclaimed and the receiver configuration is 
reset to the default values. An entity wishing to claim an sFlowRcvrTable entry must ensure that the 
entry is unclaimed before trying to claim it. The entry is claimed by setting the owner string to a 
non-null value. The entry must be claimed before assigning a receiver to a sampler or poller.
Format
sflow sampler {rcvr-indx | rate sampling-rate | maxheadersize size}
Mode
Interface Config