Netgear M4300-12X12F (XSM4324S) - Stackable Managed Switch with 24x10G including 12x10GBASE-T and 12xSFP+ Layer 3 User Manual
Stacking
159
M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual
The following table describes the nonconfigurable Stack Configuration fields.
The following table describes the nonconfigurable Stack Status information that is displayed.
Table 59. Stack Configuration
Field
Description
Hardware Management
Preference
Preference
The hardware management preference of the switch. The hardware
management preference can be disabled or unassigned.
management preference can be disabled or unassigned.
Standby Status
Identifies the switch that is configured as the standby unit. The possible
values are as follows:
values are as follows:
•
Cfg Standby
. Indicates that the unit is configured as the standby unit.
The unit configured as the standby switch becomes the stack manager if
the current manager fails.
the current manager fails.
•
Opr Standby
. Indicates that this unit is operating as the standby unit
and the configured standby unit is not part of the stack.
•
None
. The switch is not configured as the standby unit.
Switch Status
The status of the selected unit. The possible values are as follows:
•
OK
•
Unsupported
•
Code Mismatch
•
Config Mismatch
•
Not Present
Table 60. Stack Status nonconfigurable fields
Field
Description
Hardware Management
Preference
Preference
The hardware management preference of the switch, which can be
disabled or unassigned.
disabled or unassigned.
Standby Status
Identifies the switch that is configured as the standby unit:
•
Cfg Standb
y. The unit is configured as the standby unit. The unit
configured as the standby switch becomes the stack manager if
the current manager fails.
the current manager fails.
•
Opr Standb
y. This unit is operating as the standby unit and the
configured standby Unit is not part of the stack.
•
None
. The switch is not configured as the standby unit.
Switch Status
The status of the selected unit. Possible values are as follows:
•
OK
. The unit is connected and works properly.
•
Unsupported
. The type of inserted unit is not supported.
•
Code Mismatch
. The code version is not identical to the
master/management unit.
•
Config Mismatch
. The inserted device type is different from the
configured devices.
•
Not Present
. The unit is not connected.
•
SDM Mismatch
. SDM template mismatch.
•
Updating Code
. A code update is in progress.
•
STM Mismatch
. STM template mismatch.