Chapter 2.  Configuring System Information 
 
ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual 
Default value is Disable.
2. 
Use Port to specify the local UDP port to listen for responses/broadcasts. Allowed range is 
1 to 65535. Default value is 123.
3. 
Use Unicast Poll Interval to specify the number of seconds between unicast poll requests 
expressed as a power of two when configured in unicast mode. Allowed range is (6 to 10). 
Default value is 6.
4. 
Use Broadcast Poll Interval to specify the number of seconds between broadcast poll 
requests expressed as a power of two when configured in broadcast mode. Broadcasts 
received prior to the expiry of this interval are discarded. Allowed range is (6 to 10). Default 
value is 6.
5. 
Use Unicast Poll Timeout to specify the number of seconds to wait for an SNTP response 
when configured in unicast mode. Allowed range is (1 to 30). Default value is 5.
6. 
Use Unicast Poll Retry to specify the number of times to retry a request to an SNTP server 
after the first time-out before attempting to use the next configured server when configured in 
unicast mode. Allowed range is (0 to 10). Default value is 1.
7. 
When using SNTP/NTP time servers to update the switch's clock, the time data received 
from the server is based on Coordinated Universal Time (UTC) which is the same as 
Greenwich Mean Time (GMT). This may not be the time zone in which the switch is located.  
 
Use Time Zone Name to configure a timezone specifying the number of hours and 
optionally the number of minutes difference from UTC with Offset Hours and Offset Minutes. 
The time zone can affect the display of the current system time. The default value is UTC.
8. 
Use Offset Hours to specify the number of hours difference from UTC. See Time Zone 
Name (
is 0.
9. 
Use Offset Minutes to specify the number of Minutes difference from UTC. See Time Zone 
Name (
0.