Chapter 2.  Configuring System Information 
 
ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual 
The following table describes the Stack Configuration fields.
Table
 
2-29. 
Field
Description
Hardware Management Preference
The hardware management preference of the switch. 
The hardware management preference can be 
disabled or unassigned.
Switch Status
Displays the status of the selected unit. The possible 
values are:
• 
OK
• 
Unsupported
• 
Code Mismatch
• 
Config Mismatch
• 
Not Present
Management Status
Displays whether the selected switch is the 
management unit or a normal stacking member or on 
standby.
Stack Status
The following table describes the Stack Status fields.
Table
 
2-30. 
Field
Description
Unit ID
Unit Id of the specific switch.
Switch Description
The description for the unit can be configured by the 
user.
Serial Number
The unique box serial number for this switch.
Up Time
Displays the relative time since the last reboot of the 
switch.
Configured Model Identifier
This field displays the model type assigned by the 
device manufacturer to identify the device.
Plugged-in Model Identifier
 This field displays the model type assigned by the 
device manufacturer to identify the plugged-in 
device.
Expected Code Type
This field indicates the expected code type on this 
unit.
Running Code Version
This field indicates the detected version of code on 
this unit.
Code Version in Flash
Displays the Release number and version number of 
the code stored in flash.