Install The Protector System
®
(Continued)
MOUNTING AND WIRING THE SAFETY REVERSING SENSORS
Mounting:
1. Slide a 1/4"-20x1/2" carriage bolt head into the slot on each
sensor. Use wing nuts to fasten sensors to brackets, with
lenses pointing toward each other across the door. Be sure the
lens is not obstructed by a bracket extension (Figure 5).
2. Finger tighten the wing nuts.
Option A - Installation Without Pre-Wiring:
1. Run the bell wire from both sensors to the garage door
opener. Attach the wire to the wall and ceiling with the staples
(Figure 6).
Option B - Pre-Wired Installation:
If your garage already has wires installed for the safety reversing
sensors, follow the instructions below:
1. Cut the end of the safety sensor wire, making sure there is
enough wire to reach the pre-installed wires from the wall
(Figure 7).
2. Separate the safety sensor wires and strip 7/16 inch (11 mm)
of insulation from each end. Choose two of the pre-installed
wires and strip 7/16 inch (11 mm) of insulation from each end.
Make sure that you choose the same color pre-installed wires
for each sensor (Figure 8).
3. Connect the pre-installed wires to the sensor wires with wire
nuts making sure the colors correspond for each sensor
(Figure 9).
CONNECT TO GARAGE DOOR OPENER:
1. Strip 7/16 inch (11 mm) of insulation from each set of wires.
Separate white and white/black wires sufficiently to connect to
the opener quick-connect terminals. Twist like colored wires
together. Insert wires into quick-connect holes: white to white
and white/black to grey (Figure 10).
Safety Reversing 
Sensor
Safety Reversing 
Sensor
1. Strip wire 7/16" (11 mm)
7/16" (11 mm)
2. Twist like colored 
wires together
3. To insert or release 
wire, push in tab with 
screwdriver tip
Quick-Connect Terminals
Red White Grey
Bell Wire
Bell Wire
Invisible Light Beam
Protection Area
Connect Wire to
Quick-Connect Terminals
Finished
Ceiling
Figure 10
Figure 5
Figure 6
Figure 7
Figure 9
Figure 8
Carriage 
Bolt
Wing 
Nut
Safety Reversing
Sensor Wires
7/16"
(11 mm)
7/16"
(11 mm)
Pre-Installed Wires
Not Provided
Pre-Installed
Wires
Safety
Reversing
Sensor
Wires
White
White/Black
25