Honeywell Electrode Humidifier [with HumidiPRO™ H6062 Digital Humidity Control (HM700A1000)] Installation Guide
HM700A1000
11
33-00118EFS—01
Fig. 16. Primary power connection.
NOTES:
—
Honeywell requires the use of a GFI circuit on this device to protect the homeowner from electrical shock.
—
When installed correctly, the green wire should be removed from the drain valve. The green wire comes pre-installed
from the factory to protect the homeowner in case of an improper installation or when it is not possible to retrofit a GFI
circuit. See Fig. 24 for the location of green wire on the drain valve.
—
Ensure that adequate power is available to carry full humidifier amp draw as indicated on the specification label.
—
Do not use neutral wire as a ground; connect a dedicated ground to ground termination.
—
All wiring to be in accordance with national and local electrical codes.
HOT
HOT
HOT
GROUND
P
240
240
120
L1
L1
GROUND
E
X
T
I
N
T
240 VAC (1 PHASE)
120 VAC (1 PHASE)
NEUTRAL
HOT
GROUND
P
240
240
120
L1
L1
GROUND
NOTE: CONNECT 120 VAC,
“HOT”, TO L1
(OPTIONAL)
(OPTIONAL)
NOTE: POWER WIRES
CAN ALSO BE ROUTED
THROUGH OPENING IN
BACK OF CABINET
M35806