Cisco Cisco TelePresence MCU 4510 Release Notes

Page of 16
Limitations
Cisco TelePresence MCU 4.5(1.45) Software Release Notes
Page 12 of 16
CTS does not see content on joining or after hold/resume
If calling a CTS into (or out from) a conference that already has content, it does not display it.  Similarly it does 
not see content it was previously seeing after hold/resume. Restarting the content works.  (Issue identifier 
CSCum68244)
Busy message not sent when port limit is reached
The MCU returns a TRYING message once the port limit is reached instead of a 486 busy message. This is 
only an issue when MCU is directly trunked from Cisco Unified Communications Manager.  We recommend 
deploying the MCU(s) behind Cisco TelePresence Conductor to avoid this.
The MCU does not support sender-side flow control
The MCU does not support sender-side media flow control. This can create problems when calls are made 
over low bandwidth pipes to endpoints that do not support receive-side flow control. In such calls, flow 
control is not possible for the media from the MCU to the endpoint. To assist in this situation low bandwidth 
can be set on the endpoint.
Unable to add a VNC user on Windows 7 for MCU
It is not possible to add a VNC user to an MCU conference if the VNC user is running Windows 7 on their 
desktop. This is an issue on the Microsoft side - the connection will attempt to call out but fail. In the MCU 
logs the following error message will appear: Connect failed with errno 60. The workaround is for 
the VNC user to upgrade to Windows 7 SP1 and apply the necessary updates.  (Issue identifier 
CSCun87357) 
Slot 10 of the Cisco TelePresence MSE 8000 chassis does not support 
clustering
Slot 10 of the Cisco TelePresence MSE 8000 chassis does not support clustering in this MCU software 
release. However, slot 10 in the same chassis as a cluster can be used for a standalone blade of any type.   
(Issue identifier CSCtr53874) 
MCU times out outbound SIP call after 64 seconds  
If an outbound SIP call from an MCU takes longer than 64 seconds to connect, the MCU may time-out the 
call before call set-up is complete.  (Issue identifier CSCum70556) . To work around this:
 
Reduce the call setup time by reconfiguring other nodes in the call path, or 
 
Use H.323, which has a longer timeout. (The Cisco TelePresence VCS can interwork between H.323 and 
SIP.)
Windows Media Player streaming only works over HTTP
Windows Media Player (WMP) streaming will work if the protocol is set to HTTP or Auto-negotiate, but there 
may be a delay in connection for auto-negotiate. MMS streaming will fail, and has also been removed from 
WMP 11 and onwards.