Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-35
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Regular maintenance
Installing the new modem
Refer to th
 for directions on how to install 
and connect the modem for both T1 CAS and T1 PRI/E1 systems.
Regular maintenance
This section explains the regular maintenance needed to keep the 8112 server up and running.
Replacing the power supply unit fan filter
The filter in the power supply unit fan needs to be replaced on a regular basis. The frequency of the 
replacement depends on how much dust is in the air. On average, the filter should be replaced once a 
year. To replace the power supply unit fan filter, refer to the 
In addition, if any of the following alarms are seen, immediately check the power supply unit fan and its 
filter:
0x70034 (MAJOR) Temperature out of range
0x700BB (MINOR) Power supply fan N is failing
0x700C6 (MINOR) Power supply N cooling failure
Enabling server disk capacity monitoring (optional)
MeetingPlace Audio Server 5.2 provides the ability to monitor disk use. It raises an alarm when it 
reaches or exceeds a specified use threshold. To enable disk capacity monitoring, follow this procedure.
Step 1
If not already connected, access the CLI by following the procedures in the 
 and 
Step 2
Login as a technician. The tech$ prompt appears.
Step 3
Turn on terminal logging. For information on logging, see 
.
Step 4
Type 
configdiskcap
 and press Enter
 appears.