Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
A-59
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Appendix A      CLI Reference
  span
span
Summary
The “span” command views or modifies a T1 CAS span record.
Description
The “span” command is used to view or modify a T1 CAS span record in the database. This tells the 
system whether the span should be active, various characteristics of the span, and the mapping between 
trunks and internal port numbers.
The following characteristics are set by the “span” command:
Framing — D4 or ESF. The framing protocol used on this span. This is determined by the service 
provider. We recommend using ESF only.
Zero code suppression — none, B8ZS, or jammed bit. This protocol is determined by the service 
provider. We recommend using B8ZS only.
Timing — external or internal. This determines whether the span is permitted to supply trunk timing 
for the system. Specify external if the span is connected to the public network or a trusted system. 
At least one span should always be designated external.
External sync priority — a number (1-255) or never that controls the priority (1 is highest, 255 is 
lowest) of the spans that are set for external timing. The system picks the highest priority operational 
span to provide the timing. If two spans have the same priority, the lower numbered span is used.
Remote loopback to network? — y or n. If yes, this puts the span into a loopback mode for testing 
from the remote end. For normal operation, set to n.
Internal data loopback? — y or n. If yes, this causes the span to loop back locally for running 
diagnostics. For normal operation, set to n.
Options
After typing 
span
 and pressing Enter, the following menu appears:
1) View DTI span record(s) — prompts the user to select a specific span or all spans. The system 
displays whether the card is active, the characteristics of the span, and the port number of each trunk.
2) Modify DTI span record — prompts the user to select a specific span, then prompts the user for 
whether the span should be active, the characteristics of the span, and the port number assignment 
for each trunk.
x) Exit — exits the “span” command.
Note
For each voice processor unit, the spans are numbered 0-4. Trunks on a span are numbered 1-24. Ports 
are numbered 0-119 (or the number of licensed access ports minus 1). There are up to four span records 
for each Smart Blade.
Note
The span record is referenced by both a Smart Blade record (see the “blade” command) and each port 
record (configured from the port command and MeetingTime). It is important to be sure that these 
references are consistent. If a port is referenced in a span record, the corresponding port record must 
reference that span.