Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
3-33
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 3      Installing the 8112 Server
  Connecting the system cables
Step 7
Repeat steps 5 and 6 above for the second trunk card cable assembly (50-pin Amphenol cable) for the 
first Multi Access Blade. It should go into the connector on the left side of the breakout box and on the 
right side of the Multi Access Blade in the connector labeled spans 9-16.
Step 8
Repeat steps 5, 6, and 7 above for the trunk card cable assemblies (50-pin Amphenol cables) for the 
second Multi Access Blade.
Connecting telephony cables for pure IP systems
Pure IP systems are configurations that only use IP functionality and do not have use any T1 CAS, T1 
PRI or E1 functionality.
Note
Pure IP systems do not use a breakout box.
All MeetingPlace servers with IP configurations are shipped with the necessary number of Multi Access 
Blades. Also shipped are the necessary number of IP LAN cables. The number of IP LAN cables you 
receive depends on the number of Multi Access Blades in your system. You need one IP LAN cable for 
every Multi Access Blade.
Looking at the back of the server, the Multi Access Blade transition modules for IP configurations begin 
in slot 16 on the left and move to the right. The Smart Blades begin in slot 1 and move to the left. They 
do not have any cables connected to them.
To connect the IP LAN cables, follow these steps:
Step 1
Locate the Cisco Systems-supplied IP LAN cables.
Step 2
Plug the first IP LAN cable into the customer-supplied RJ-48c socket.
Step 3
Plug the other end of the first IP LAN cable into the Ethernet 1 connector on the Multi Access Blade.
Step 4
Repeat steps 2 and 3 if you have more than one Multi Access Blade for the IP configuration.
 illustrates the 8112 server’s connections from the back of the server. This configuration 
supports 480 IP ports with one MA-16.