Cisco Cisco Unified MeetingPlace Audio Server Installation Guide

Page of 248
4-32  Database planning 
Cisco MeetingPlace Audio Server Installation Planning Guide
February 27, 2004
Auto-answer Parameters
Mtg controls device
Whether the meeting controls 
the auto-answer device.
No
Yes/No
Connected until mtg 
ends
Whether auto-answer devices 
remain connected until meetings 
end. 
When Yes, disconnect timeout 
value is same as Disconnect 
Empty Port (min). When No
disconnect timeout value is 0.
Yes
Yes/No
Meeting Recording Settings
FF/RR playback 
incrmt (sec)
Number of seconds 
MeetingPlace fast-forwards or 
rewinds when users press 
1
 or 
while listening to meeting 
recordings on phone.
120
Numeric—4 
to 3600*
Max mtg recdg length 
(min)
Maximum recording time (in 
minutes) allowed for each 
meeting.
Recommended: Same as Max 
Meeting Length parameter.
240
Numeric—0 
to 1440*
Max mtg message 
length (sec)
Maximum length (in seconds) 
for pre-recorded single meeting 
messages.
60
Numeric—15 
to 1800*
Max voice comment 
(sec)
Maximum length (in seconds) 
for voice comments.
Numeric—15 
to 1800*
Warning at end of 
recdg?
Whether users hear warning that 
meeting recording is about to 
end. 
When Yes, attendees are warned 
that meeting recording is about 
to end. When No, attendees hear 
the final two-minute warning.
Yes
Yes/No
# of days to retain
Number of days after a meeting 
that recordings remain stored.
7
Numeric—0 
to 60*
Prompt Information
End of mtg warning 
(min)
Number of minutes before 
scheduled end time when end-
of-meeting warning is issued.
10
Numeric—to 
15*
Field
Description
Default
Options/
Field size
Value