  alarm
alarm
Summary
The alarm command lists the contents of the system alarm table.
Description
The alarm command lists the contents of the system alarm table. Each entry has two lines. The first line 
has several columns:
REFNO — A reference number used when clearing the alarm. See the clearalarm command.
SEV — Severity of the alarm: “MIN” is minor and “MAJ” is major.
CODE — Exception code. When reporting an alarm, be sure to include this code.
COUNT — A count of occurrences of this condition since the alarm table was last cleared.
FIRST — Date and time of the first occurrence since the alarm table was last cleared.
LAST — Date and time of the most recent occurrence.
SW MODULE— Used for software faults.
DEV — Used for hardware faults.
UNIT — Used for hardware faults.
PORT — Used for hardware faults.
The second line is a text description of the alarm.
SEE ALSO