Cisco Flexible Solutions Taps Data Sheet

Page of 9
Surge-Gap Taps -- Two-Way, Four-Way, Eight-Way 
Standard & Full Profile
 
 
3
 
 
Specifications, continued 
 
2-Way Surge Gap Tap – Standard Housing 
 
Tap Value 
11 
14 
17 
20 
23 
26 
29 
 
 
Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ.
Frequency                   
5 - 
3.2 
2.5 2.0
1.8
1.2
1.0
1.1
0.8 0.8
0.5 0.7 0.4 0.6 0.5
0.6 0.4
55 - 
2.5 
2.0 1.6
1.2
1.1
0.7
0.9
0.5 0.6
0.4 0.6 0.3 0.6 0.4
0.6 0.3
550 - 
3.6 
3.3 2.5
2.1
1.7
1.4
1.6
1.1 1.3
0.9 1.2 0.9 1.2 1.0
1.2 0.8
650 - 
3.9 
3.6 2.6
2.3
1.8
1.6
1.5
1.2 1.3
1.0 1.2 1.0 1.3 1.1
1.3 0.9
750 - 
4.1 
3.8 2.7
2.5
1.9
1.7
1.6
1.3 1.4
1.1 1.6 1.1 1.4 1.2
1.4 1.0
870 - 
4.3 
4.0 3.0
2.8
2.3
2.0
1.8
1.5 1.7
1.3 1.5 1.2 1.6 1.3
1.6 1.2
Insertion 
Loss  
(In-Out) 
(dB) 
1000 - 
4.6 
4.3 3.6
3.3
2.7
2.4
2.2
1.8 1.9
1.6 1.8 1.6 1.8 1.6
1.8 1.5
 
 
 
Tap Value 
11 
14 
17 
20 
23 
26 
29 
Frequency 
         
1.0 1.0 1.3 1.3 1.4 1.4 1.3 1.0 1.6 
55  1.0 1.1 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
550  1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.5 
650  1.0 1.0 1.0 1.0 1.0 1.3 1.3 1.0 1.4 
750  1.0 1.0 1.0 1.0 1.0 1.3 1.3 1.0 1.1 
870  1.1 1.3 1.0 1.0 1.0 1.2 1.1 1.0 1.0 
Tap Loss 
Tolerance  
 (
± dB) 
1000 1.3 1.7 1.0 1.0 1.4 1.2 1.0 1.5 1.2 
5-50 - 20 18 22 24 32 33 39 39 
51-550 -  26 28 30 32 35 35 41 38 
551-650 -  24 27 28 33 32 34 39 37 
651-750 -  23 28 27 33 29 32 36 36 
751-870 -  23 26 27 33 28 29 34 35 
Out-Tap 
Isolation 
(min.)  
(dB) 
871-1000 -  24 24 27 28 26 26 32 32 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Unless otherwise noted, the above specifications reflect typical station performance at stated reference levels in the recommended 
operating configuration(s).  Specifications are based upon measurements made in accordance with SCTE/ANSI standards (where 
applicable), using standard frequency assignments.