Cisco Cisco TelePresence MCU 4510 Maintenance Manual

Page of 242
Configuring network and system settings
Cisco TelePresence MCU 4.3 Product administration guide
Page 180 of 242
n
The 'system uptime' that appears in the trap is the time since SNMP was initialized on the MCU (and
therefore will differ from the Uptime reported by the MCU on the
Status > General
page).
n
The SNMP MIBs are read-only.
System information
Field
Field description
Usage tips
Name
Identifies the
MCU in the
SNMP system
MIB.
Usually you would give every device a unique name. The default setting is:
Cisco TelePresence MCU
Location
The location that
appears in the
system MIB.
An optional field. Where you have more than one MCU, it is useful to identify
where the MCU is located. The default setting is:
Unknown
Contact
The contact
details that
appear in the
system MIB.
An optional field. The default setting is:
Unknown
Add the administrator’s email address or name to identify who to contact when
there is a problem with the device. If SNMP is enabled for a port on the public
network, take care with the details you provide here.
Description
A description
that appears in
the system MIB.
An optional field, by default this will indicate the model number of the MCU.
Can be used to provide more information on the MCU.
Configured trap receivers
Field
Field description
Usage tips
Enable traps
Select this check box
to enable the MCU to
send traps.
If you do not select this check box, no traps will be sent.
Enable
authentication
failure trap
Select this check box
to enable
authentication failure
traps.
You cannot select this check box unless you have selected to Enable
traps 
above. Authentication failure traps are generated and sent to the
trap receivers when someone tries to read or write a MIB value with an
incorrect community string.
Trap receiver
addresses 1
to 4
Enter the IP address
or hostname for up to
four devices that will
receive both the
general and the
authentication failure
traps.
The traps that are sent by the MCU for IPv4 are SNMP v1 traps. For
IPv6 the MCU sends SNMP v2 traps. You can configure trap receivers
or you can view the MIB using a MIB browser. You can set the UDP
port number for the trap in the format <IP address>: <port number>. By
default the UDP port number is 162. Note that square brackets are
mandatory for IPv6 addresses.