Displaying hardware health status
The
Health status
page (
Status > Health
) displays information about the hardware components of the
MCU.
Note: The Worst status seen conditions are those since the last time the MCU was restarted.
To reset these values, click Clear. Refer to the table below for assistance in interpreting the information
displayed.
Field
Field description
Usage tips
Fans (on
MCU 4200 &
4500 Series
Voltages
RTC battery
Displays two possible
states:
n
OK
n
Out of spec
States indicate both Current
status 
and Worst status
seen 
conditions.
The states indicate the following:
n
OK - component is functioning properly
n
Out of spec - Check with your support provider; component
might require service
If the Worst status seen column displays Out of spec, but Current
status 
is OK, monitor the status regularly to verify that it was only a
temporary condition.
Temperature
Displays three possible
states:
n
OK
n
Out of spec
n
Critical
States indicate both Current
status 
and Worst status
seen 
conditions.
The states indicate the following:
n
OK - temperature of the MCU is within the appropriate range
n
Out of spec - Check the ambient temperature (should be less
than 34 degrees Celsius) and verify that the air vents are not
blocked
n
Critical - temperature of MCU is too high. An error also appears
in the event log indicating that the system will shutdown in 60
seconds if the condition persists
If the Worst status seen column displays Out of spec, but
Current status is OK monitor the status regularly to verify that it
was only a temporary condition.
Related topics
n
n
Cisco TelePresence MCU Series 4.5 Online Printable Help
Page 227 of 278
Displaying system status
Displaying hardware health status