Cisco Cisco TelePresence MCU 4510 Developer's Guide
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
device.health.query
Returns the current status of the device, such as health monitors and CPU load.
Returned data
Parameter name
Type
Short description
cpuLoad
integer
The CPU load as a percentage of the maximum.
mediaLoad
integer
A percentage value representing the proportion of the
device's media processing capacity that is currently in use.
device's media processing capacity that is currently in use.
audioLoad
integer
A percentage value representing the proportion of the
device's audio processing capacity that is currently in use.
device's audio processing capacity that is currently in use.
videoLoad
integer
A percentage value representing the proportion of the
device's video processing capacity that is currently in use.
device's video processing capacity that is currently in use.
fanStatus
string
One of ok, outOfSpec, or critical.
fanStatusWorst
string
One of ok, outOfSpec, or critical.
temperatureStatus
string
The current temperature status. One of ok, outOfSpec, or
critical
critical
. The device will shutdown if the critical status
persists.
temperatureStatusWorst
string
The worst temperature status recorded on this device since
it booted. One of ok, outOfSpec, or critical.
it booted. One of ok, outOfSpec, or critical.
rtcBatteryStatus
string
The current status of the RTC battery (Real Time Clock).
One of ok, outOfSpec (the battery is operating outside of
the normal range, and may require service), or critical.
One of ok, outOfSpec (the battery is operating outside of
the normal range, and may require service), or critical.
rtcBatteryStatusWorst
string
The worst recorded status of the RTC battery. One of ok,
outOfSpec
outOfSpec
(the battery has operated outside of the normal
range at some time since the device was booted), or
critical
critical
.
voltagesStatus
string
ok
, outOfSpec (the voltage is currently outside the normal
range), or critical.
voltagesStatusWorst
string
ok
, outOfSpec (the voltage has been outside the normal
range at some time since the device last booted), or
critical
critical
.
operationalStatus
string
One of active, shuttingDown, or shutdown.
Cisco TelePresence MCU API 2.10
Page 81 of 296
API commands
device.health.query