temperatureStatus
string
The current temperature status. One of okoutOfSpec, or
critical
. The device will shutdown if the critical status
persists.
temperatureStatus
is used in: 
temperatureStatusWorst
string
The worst temperature status recorded on this device since
it booted. One of okoutOfSpec, or critical.
Value
Description
ok
The temperature has been within the normal operating range since the
device was booted.
outOfSpec
The temperature has been outside the normal operating range at least once
since the device was booted.
critical
At some point since the last boot the temperature was too high. The device
will shutdown if this condition persists.
temperatureStatusWorst
is used in: 
.
templateName
string
The name of the template. When passed in a call, this
parameter identifies the template that is used for the
purpose of the call.
templateName
is used in: 
,
templateNumber
integer
An index that uniquely identifies the template. Template
numbers are not preserved when the MCU reboots.
The index number of the template. When passed in a call, this parameter identifies the template that is
used for the purpose of the call.
The MCU assigns a templateNumber and returns it in response to a template.create call.
Value
Description
0
The top level template
1
The first created template
2
The second created template. templateNumber increments as new
templates are created
templateNumber
is used in: 
.
templates
array of
structs
Each array element is a struct that contains the parameters
that define a template.
templates
is used in: 
.
Cisco TelePresence MCU API 2.10
Page 269 of 296
Index of parameters
Index of parameters: T