Cisco Cisco UCS C260 M2 Rack Server Data Sheet

Page of 80
Cisco UCS C460 M4 High-Performance Rack-Mount Server
CONFIGURING the SERVER
43
STEP 10
ORDER POWER SUPPLIES
The available power supplies are listed in 
Caveats
If you select the UCSC-PSU2V2-1200W: you must select four of these power supplies. You 
cannot select any GPUs when you use these power supplies.
For the UCSC-PSU2-1400W: if there are 2 CPUs and 0 GPUs and the quantity of 64 GB DIMMs 
is less than or equal to 32, either two or four of these power supplies can be configured; 
otherwise, four power supplies are required. Use these power supplies only with v2 CPUs 
(not v3 CPUs).
For the UCSC-PSUV2-1400W: if there are 2 CPUs and 0 GPUs and the quantity of 64 GB DIMMs 
is less than or equal to 32, either two or four of these power supplies can be configured; 
otherwise, four power supplies are required.
Table 23
  Power Supplies
Product ID (PID)
PID Description
UCSC-PSU2V2-1200W
1
Notes . . .
1. The power output is 1200W with a 200-240V input and 800W with a 100-120V input.
1200W/800W V2 AC Power Supply for 2U C-Series Servers
UCSC-PSU2-1400W
1400W AC Power Supply (200 - 240V) 2U & 4U C Series Servers
UCSC-PSU2V2-1400W
1400W AC Power Supply (200 - 240V) 2U & 4U C Series Servers