Bosch GLL 2-80 P 0601063200 User Manual

Product codes
0601063200
Page of 302
18 | English 
1 609 929 S04 | (30.6.09)
Bosch Power Tools
Switching On and Off
To switch on the measuring tool, slide the 
On/Off switch 7 to the “ on” position (when 
working without automatic levelling) or to the 
on” position (when working with automatic 
levelling). Immediately after switching on, the 
measuring tool sends laser beams out of the exit 
openings 1.
f
Do not point the laser beam at persons or 
animals and do not look into the laser beam 
yourself, not even from a large distance.
To switch off the measuring tool, slide the 
On/Off switch 7 to the “off” position. When 
switching off, the levelling unit is locked.
When exceeding the maximum permitted oper-
ating temperature of 45 °C, the measuring tool 
switches off to protect the laser diode. After 
cooling down, the measuring tool is ready for 
operation and can be switched on again.
Deactivating the Automatic Shut-off
When no button on the measuring tool is 
pressed for approx. 30 minutes, the measuring 
tool automatically switches off to save the bat-
teries.
To switch on the measuring tool after automatic 
shut-off, either slide the On/Off switch 7 to the 
“off” position and then switch the measuring 
tool on again or press the operating mode but-
ton 4 once or press the pulse-function button 3 
once.
To deactivate the automatic shut-off, keep the 
operating mode button 4 pressed for at least 3 s 
(while the measuring tool is switched on). Deac-
tivation of the automatic shut-off is confirmed 
by brief flashing of the laser beams.
f
Do not leave the switched on measuring 
tool unattended and switch the measuring 
tool off after use. 
Other persons could be 
blinded by the laser beam.
To activate the automatic shut-off, switch the 
measuring tool off and then on again or press 
and hold the operating mode button 4 for at 
least 3 s.
Deactivating the Signal Tone
After the measuring tool has been switched on, 
the audio signal is always activated.
To deactivate/activate the audio signal, press 
and hold the operating mode button 4 and the 
pulse-function button 3 at the same time for at 
least 3 s.
The audio signal activation and deactivation are 
both confirmed by three short beeps.
Operating Modes
The measuring tool has three operating modes 
between which you can switch at any time:
– Horizontal operation: generates a horizontal 
laser plane,
– Vertical operation: generates a vertical laser 
plane,
– Cross-line operation: generates a horizontal 
and vertical laser plane.
After switching on, the measuring tool is in hor-
izontal operation. Press the operating mode 
button 4 to change the operating mode.
All three operating modes can be selected either 
with or without automatic levelling.
Pulse Function
When working with the laser receiver 17, the 
pulse function must be activated, – independ-
ent of the selected operating mode.
In pulse function, the laser lines flash at very 
high frequency and thus become detectable by 
the laser receiver 17.
To switch on the pulse function, press button 3
When the pulse function is switched on, the 
pulse-function indicator 5 lights up green. 
When the pulse function is switched on, the vis-
ibility of the laser lines is reduced for the human 
eye. Therefore, shut off the pulse function by 
pushing button 3 again when working without 
laser receiver. When the pulse function is 
switched off, the pulse-function indicator 5 is 
deactivated.
OBJ_BUCH-907-001.book  Page 18  Tuesday, June 30, 2009  2:32 PM