Cisco Cisco NAC Appliance 4.1.0

Page of 506
Cisco NAC Appliance - Clean Access Manager Installation and Administration Guide
OL-12214-01
Chapter 4      Switch Management: Configuring Out-of-Band (OOB) Deployment
Configure OOB Switch Management in the CAM
Fast Ethernet ports and 2 Gigabit Ethernet uplinks, the Ports tab will display 26 rows, with one entry 
per port. Trunk ports configured on the switch are distinguished by blue background on the Ports page, 
and VLAN values for these ports refer to the trunk port native VLAN. 
If the switch does not support mac-notification traps, the Setup button (Set up mac-notification on 
managed switch ports
) and MAC Not. column are not displayed on the page. In this case, 
Linkup/Linkdown traps must be supported and configured on the switch and Clean Access Manager. See 
 for how the Ports page displays in this case. 
Ports —MAC Notification
Figure 4-23
Ports Tab 
After adding a new switch, set up the Ports configuration page (
) for the switch ports as 
follows:
1.
Choose the Profile (
) to use for the port, either managed or unmanaged.
2.
Click Update (
) to save the Port Profile for the port to the CAM. 
3.
Click Setup (
) to initialize mac-notification on switch ports (if available on the switch). 
4.
Click Save (
) to save the switch running configuration to the switch stored (startup) 
configuration. 
Description
The buttons and dropdown menus for the Ports configuration page are detailed below:
  •
Reset All (Initial VLAN Port Profiles only) 
1
2
3
4
Dynamic;
reflects values
Reflects values
in CAM DB
Reflects
values 
on switch 
in CAM DB