Cisco Cisco ASR 5000

Page of 9109
  Context Configuration Mode Commands N-R 
radius accounting rp  ▀   
 
Command Line Interface Reference, StarOS Release 18  ▄  
 
   
2711 
trigger-event { active-handoff | active-start-param-change | active-stop }
 
Configures the events for which a RADIUS event is generated for accounting as one of the following: 
 
active-handoff
: Disables a single R-P event (and therefore a RADIUS accounting event) when an 
Active PCF-to-PFC Handoff occurs. Instead, two R-P events occur (one for the Connection Setup, 
and the second for the Active-Start). Default: Disabled 
 
active-start-param-change
: Disables an R-P event (and therefore a RADIUS accounting event) 
when an Active-Start is received from the PCF and there has been a parameter change. Default: 
Enabled 
 
active-stop
: Disables an R-P event (and therefore a RADIUS accounting event) when an Active-
Stop is received from the PCF. Default: Disabled 
Important:
  This keyword has been obsoleted by the 
trigger-policy
 keyword. Note that if this command is 
used, if the context configuration is displayed, RADIUS accounting RP configuration is represented in terms of the 
trigger-policy. 
trigger-policy { airlink-usage [ counter-rollover ] | custom [ active-handoff | 
active-start-param-change | active-stop ] | standard }
 
Default:
airlink-usage
: Disabled 
custom
 
active-handoff
: Disabled 
 
active-start-param-change
: Disabled 
 
active-stop
: Disabled 
 
standard
:Enabled 
Configures the overall accounting policy for R-P sessions as one of the following: 
 
airlink-usage [ counter-rollover ]
:Designates the use of Airlink-Usage RADIUS accounting 
policy for R-P, which generates a start on Active-Starts, and a stop on Active-Stops. 
If the 
counter-rollover
 option is enabled, the system generates a STOP/START pair before input/output 
data octet counts (or input/output data packet counts) become larger than (2^32 - 1) in value. This setting is 
used to guarantee that a 32-bit octet count in any STOP message has not wrapped to larger than 2^32 thus 
ensuring the accuracy of the count. The system, may send the STOP/START pair at any time, so long as it 
does so before the 32-bit counter has wrapped. Note that a STOP/START pair is never generated unless the 
subscriber RP session is in the Active state, since octet/packet counts are not accumulated in the Dormant 
state. 
 
custom
: specifies the use of custom RADIUS accounting policy for R-P. The custom policy can consist 
of the following: 
 
active-handoff
: Enables a single R-P event (and therefore a RADIUS accounting event) when an 
Active PCF-to-PFC Handoff occurs. Normally two R-P events will occur (one for the Connection 
Setup, and the second for the Active-Start). 
 
active-start-param-change
: Enables an R-P event (and therefore a RADIUS accounting event) 
when an Active-Start is received from the PCF and there has been a parameter change. 
Important:
  Note that a custom trigger policy with only 
active-start-param-change
 enabled is identical to 
the 
standard
 trigger-policy.