Cisco Cisco ASR 5000

Page of 9109
Exec Mode Commands (D-S)   
▀  hd raid 
 
 
▄  Command Line Interface Reference, StarOS Release 18 
4116 
   
insert
 
local1
 | 
remote1
 
On the ASR 5000, inserts the specified disk to the running RAID causing it to recover from degraded mode. 
local1:
 specifies the primary SMC is to be inserted into the RAID. 
remote1:
 specifies the backup SMC is 
to be inserted into the RAID. 
insert
 
hd_num
 
On the ASR 5500, inserts the specified FSC disk array into the running RAID causing it to recover from 
degraded mode. 
hd_num
 specifies the RAID is to be established on the FSC in slot numbers 13 through 18 (hd13, hd14, ... 
hd18).  
insert
 
{ | local1 | local2 }
 
On VPC, inserts the specified vHD into the running RAID causing it to recover from degraded mode. 
overwrite
 
local1
 | 
remote1
 
On the ASR 5000, overwrites the specified disk and adds it to the current running RAID to construct a fully 
mirrored array. 
local1
 specifies the primary SMC is to be added to the current RAID. 
remote1
 specifies the backup SMC 
is to be added to the current RAID. 
overwrite
 
hd_num
 
On the ASR 5500, overwrites the specified FSC disk array and adds it to the current running RAID to 
construct a fully mirrored array. 
hd_num
 specifies the RAID is to be established on the FSC in slot numbers 13 through 18 (hd13, hd14, ... 
hd18).  
overwrite
 
{ local1 | local2 }
 
On VPC, overwrites the specified vHD and adds it to the current running RAID to construct a fully mirrored 
array. 
quarantine [ directory
 
pathname
 
| limit
 
number_files
 
| mtime
 
minutes
 
Recovers and quarantines dirty-degraded RAID files. 
directory
 specifies the pathname where files are to be quarantined. 
pathname
 is expressed as an 
alphanumeric string of 1 through 29 characters. 
limit
 sets the maximum number of files to quarantine. 
number_files
 is an integer from 0 to 1000000. 
mtime
 specifies the number of minutes ago during which modified files will be quarantined. 
minutes
 is an 
integer from 0 through 1440. 
remove
 
local1
 | 
remote1
 
On the ASR 5000, removes the specified disk from the running RAID causing it to run in degraded mode or 
to fail. 
local1:
 specifies the primary SMC is to be removed from the RAID. 
remote1:
 specifies the backup SMC 
is to be removed from the RAID. 
remove
 
hd_num
 
On the ASR 5500, removes the specified FSC disk array from the running RAID causing it to run in degraded 
mode or to fail.