Cisco Cisco ASR 5000
FA Service Configuration Mode Commands
▀ threshold reg-reply-error
▄ Command Line Interface Reference, StarOS Release 18
5092
Usage
Use this command to set an alert or an alarm when the number of registration reply errors is equal to or
greater than a specified number of calls per second.
Alerts or alarms are triggered for the number of registration reply errors on the following rules:
greater than a specified number of calls per second.
Alerts or alarms are triggered for the number of registration reply errors on the following rules:
Enter condition: Actual number of registration reply errors > High Threshold
Clear condition: Actual number of registration reply errors £ Low Threshold
Example
The following command configures a registration reply error threshold of
1000
and a low threshold of
500
for a system using the Alarm thresholding model:
threshold reg-reply-error 1000 clear 500