Global Configuration Mode Commands (T-threshold phspc)   
▀  threshold aaa-acct-archive-size 
 
 
▄  Command Line Interface Reference, StarOS Release 18 
5598 
   
Alerts or alarms are triggered for accounting failures based on the following rules: 
 
Enter condition: Actual number of archived messages that is greater than or equal to the high 
threshold. 
 
Clear condition: Actual number of archived messages that is less than the low threshold. 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Refer to the 
threshold poll
 command to configure the polling interval and the 
threshold monitoring
 
command to enable thresholding for this value. 
Example
 
The following command configures a high threshold count of 
250
 AAA accounting archived messages and 
low threshold of 
100
 for a system using the Alarm thresholding model: 
threshold aaa-acct-archive-size 250 clear 100