  Global Configuration Mode Commands (T-threshold phspc) 
threshold call-reject-no-resource  ▀   
 
Command Line Interface Reference, StarOS Release 18  ▄  
 
   
5629 
threshold call-reject-no-resource 
Configures alarm or alert thresholds on the system for calls rejected due to insufficient resources. 
Product
 
All 
Privilege
 
Security Administrator, Administrator 
Mode
 
Exec > Global Configuration 
configure
 
Entering the above command sequence results in the following prompt: 
[local]host_name(config)# 
Syntax
 
threshold call-reject-no-resource high_thresh [ clear low_thresh ] 
high_thresh
 
Default: 0 
Specifies the high threshold number of no-resource call rejects issued by the system that must be met or 
exceeded within the polling interval to generate an alert or alarm. 
The number is an integer from 0 through 100000. A value of 0 disables the threshold. 
clear
 
low_thresh
 
Default: 0 
Specifies the low threshold number of no-resource call rejects issued by the system that maintains a 
previously generated alarm condition. If the number of rejections falls beneath the low threshold within the 
polling interval, a clear alarm will be generated. 
The number is an integer from 0 through 100000. A value of 0 disables the threshold. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage 
No resource call reject thresholds generate alerts or alarms based on the total number of calls that were 
rejected by the system due to insufficient or no resources (memory and/or session licenses) during the 
specified polling interval. 
Alerts or alarms are triggered for no-resource-rejected calls based on the following rules: 
 
Enter condition: Actual number of calls rejected due to no resources is greater than or equal to the 
high threshold. 
 
Clear condition: Actual number of calls rejected due to no resources is less than the low threshold. 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.