Cisco Cisco ASR 5000

Page of 9109
  Global Configuration Mode Commands (T-threshold phspc) 
threshold dcca-unknown-rating-group  ▀   
 
Command Line Interface Reference, StarOS Release 18  ▄  
 
   
5663 
Alerts or alarms are triggered for unknown rating groups based on the following rules: 
 
Enter condition: Actual number of unknown rating groups is greater than or equal to the high 
threshold. 
 
Clear condition: Actual number of unknown rating groups is less than the low threshold. 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Example
 
The following command configures a high threshold count of 
250
 unknown rating groups and low threshold 
of 
100
 for a system using the Alarm thresholding model: 