Cisco Cisco ASR 5000
Global Configuration Mode Commands (threshold ppp - url-blacklisting)
▀ threshold rp-setup-fail-rate
▄ Command Line Interface Reference, StarOS Release 18
5954
threshold rp-setup-fail-rate
Configures alarm or alert thresholds for the percentage of RAN PDSN (RP) setup failures.
Product
PDSN
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold rp-setup-fail-rate high_thresh [ clear low_thresh ]
high_thresh
Default: 0
Specifies the high threshold rate percentage for RP setup failures experienced by the system that must be met
or exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold rate percentage for RP setup failures experienced by the system that must be met
or exceeded within the polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 100. A value of 0 disables the threshold.
clear low_thresh
Default: 0
Specifies the low threshold rate percentage for RP setup failures experienced by the system that maintains a
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within
the polling interval, a clear alarm will be generated.
Specifies the low threshold rate percentage for RP setup failures experienced by the system that maintains a
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within
the polling interval, a clear alarm will be generated.
low_thresh
is an integer from 0 through 100. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
RP setup failure rate thresholds generate alerts or alarms based on the rate of call setup failures experienced
by the system during the specified polling interval. The failure rate is the percentage of failures as determined
by number of Registration Request Messages rejected divided by the total number of Registration Request
Messages received.
Alerts or alarms are triggered for RP setup failure rates based on the following rules:
by the system during the specified polling interval. The failure rate is the percentage of failures as determined
by number of Registration Request Messages rejected divided by the total number of Registration Request
Messages received.
Alerts or alarms are triggered for RP setup failure rates based on the following rules:
Enter condition: Actual number of call setup failures is greater than or equal to the high threshold.
Clear condition: Actual number of call setup failures is less than the low threshold.
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
of the polling interval.