The Default alarm profile list contains alarm and condition severities that correspond when applicable to
default values established in Telcordia GR-474-CORE.
Note
All default or user-defined severity settings that are Critical (CR) or Major (MJ) are demoted to Minor
(MN) in non-service-affecting situations as defined in Telcordia GR-474-CORE.
Note
To see the full list of profiles, including those available for loading or cloning, click the Available button.
You must load a profile before you can clone it.
Tip
Up to 10 profiles, including the two reserved profiles (Inherited and Default) can be stored in CTC.
Note
Wherever it is applied, the Default alarm profile sets severities to standard Telcordia GR-474-CORE settings. In the Inherited profile,
alarms inherit, or copy, severity from the next-highest level. For example, a card with an Inherited alarm profile copies the severities
used by the node housing the card. If you choose the Inherited profile from the network view, the severities at the lower levels (node
and card) are copied from this selection.
You do not have to apply a single severity profile to the node-, card-, and port-level alarms. Different profiles can be applied at
different levels. You could use the inherited or default profile on a node and on all cards and ports, but apply a custom profile that
downgrades an alarm on one particular card. For example, you might choose to downgrade an OC-N unequipped path alarm (UNEQ-P)
from Critical (CR) to Not Alarmed (NA) on an optical card because this alarm raises and then clears every time you create a circuit.
UNEQ-P alarms for the card with the custom profile would not display on the Alarms tab (but they would still be recorded on the
Conditions and History tabs.)
When you modify severities in an alarm profile:
• All Critical (CR) or Major (MJ) default or user-defined severity settings are demoted to Minor (MN) in Non-Service-Affecting
(NSA) situations as defined in Telcordia GR-474.
• Default severities are used for all alarms and conditions until you create a new profile and apply it.
The Load and Store buttons are not available for Retrieve and Maintenance users.
The Delete and Store options will only display nodes to delete profiles from or store profiles to if the user has provisioning permission
for those nodes. If the user does not have the proper permissions, CTC greys out the buttons and they are not available to the user.
Alarm Profile Buttons
The Alarm Profiles window displays six buttons at the bottom of the screen. The following table lists and describes each of the alarm
profile buttons and their functions.
Table 7: Alarm Profile Buttons
Description
Button
Creates a new profile.
New