Viewing Multishelf Alarmed Entities
The multishelf view in CTC shows which slots are occupied in each shelf of the configuration as shown in the following figure.
Figure 3: Navigating to Shelf View from Multishelf View
You can determine where an alarm is raised by viewing the Object column. The entry there (for example, FAC-1-3-1) tells you the
entity (“fac,” or facility), shelf, slot, and port. In shelf view, the Alarms and Conditions tabs also contain a Shelf column that indicates
where the alarmed card is located.
Multishelf-Specific Alarming
The following sections explain how Ethernet communication alarms and correlated multishelf alarms are processed in the ONS 15454
DWDM system.
Ethernet Communication Alarms
The Ethernet interface card (MS-ISC) that is required for multishelf configurations does not raise traditional Ethernet alarms, such
as CARLOSS, that apply to transponder (TXP) or muxponder (MXP) client ports. Instead, MS-ISC card alarms are raised on the
shelf as EQPT alarms. These alarms include Duplicate Shelf ID (DUP-SHELF-ID) and Shelf Communication Failure
(SHELF-COMM-FAIL).