Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 60
Alarms Suppressed for Maintenance
When you place a port in OOS,MT administrative state, this raises the alarm suppressed for maintenance (AS-MT) alarm in the
Conditions and History windows and causes subsequently raised alarms for that port to be suppressed.
AS-MT can be seen in the Alarms window as well if you have set the Filter dialog box to show NA severity
events.
Note
While the facility is in the OOS,MT state, any alarms or conditions that are raised and suppressed on it (for example, a transmit failure
[TRMT] alarm) are reported in the Conditions window and show their normal severity in the Sev column. The suppressed alarms are
not shown in the Alarms and History windows. (These windows only show AS-MT). When you place the port back into IS,AINS
administrative state, the AS-MT alarm is resolved in all three windows. Suppressed alarms remain raised in the Conditions window
until they are cleared.
Alarms Suppressed by User Command
In the node view (single-shelf mode) or shelf view (multishelf mode) Provisioning > Alarm Profiles tabs > Alarm Behavior tabs, the
ONS 15454 has an alarm suppression option that clears raised alarm messages for the node, chassis, one or more slots (cards), or one
or more ports. Using this option raises the alarms suppressed by user command, or AS-CMD alarm. The AS-CMD alarm, like the
AS-MT alarm, appears in the Conditions, and History windows. Suppressed conditions (including alarms) appear only in the Conditions
window--showing their normal severity in the Sev column. When the Suppress Alarms check box is cleared, the AS-CMD alarm is
cleared from all three windows.
AS-MT can be seen in the Alarms window as well if you have set the Filter dialog box to show NA severity
events.
Note
A suppression command applied at a higher level does not supersede a command applied at a lower level. For example, applying a
node-level alarm suppression command makes all raised alarms for the node appear to be cleared, but it does not cancel out card-level
or port-level suppression. Each of these conditions can exist independently and must be cleared independently.
Use alarm suppression with caution. If multiple CTC or TL1 sessions are open, suppressing the alarms in
one session suppresses the alarms in all other open sessions.
Caution
Multishelf Configuration Alarming
Multishelf systems can share a single IP address among shelves and also correlate optical signal alarms. Ethernet alarm-raising for
this configuration also differs from alarm-raising for single-shelf configurations. This section explains how alarms are viewed on a
multishelf configuration, how alarm locations are determined, and how multishelf alarming differs from single-shelf alarming.
16