Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 98
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Superuser only
Security Level
Disable APC only to perform specific troubleshooting or node provisioning tasks. Always enable and run
APC as soon as the tasks are completed. Leaving APC disabled can cause traffic loss.
Caution
Procedure
Step 1
From the View menu, choose Go to Network View .
Step 2
Click the Maintenance APC tabs.
Step 3
Click Refresh.
The APC Discovery dialog box appears with the discovered APC domains. It may take 10-15 seconds for all the domains
to appear. Each discovered domain will be identified as "Discovered: Domain" followed by "node name side, node name
side". If APC could not be discovered on a node, a triangle with an exclamation point appears next to the node. If this
occurs, double-click the node to display the reason. If you want to save the APC discovery results to a text file, complete
the following sub-steps. Otherwise, continue with
Step 4, on page 14
.
a) Click Save.
b) In the Save Detailed Error Dialog to File dialog box, enter the path to a local or network server where you want to save
the file, or click Browse to navigate to the directory.
c) Click OK.
Step 4
Click Close to close the APC Discovery dialog box.
Step 5
Choose the domain that you want to disable.
Only domains with a status, APC State: Enabled, can be disabled.
Step 6
Click Disable APC.
Step 7
In the APC window, verify that the Check APC State status changes to Disable.
Step 8
Return to your originating procedure (NTP).
DLP-G158 Enable Automatic Power Control
This task enables the DWDM APC.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in the "
document.
Prerequisite Procedures
As needed
Required/As Needed
14