Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 23
Procedure
Step 1
Complete the
task if an external building integrated timing supply
(BITS) source is available. This is the most common NCS timing setup method.
Step 2
If an external BITS source is not available, complete the
task. This task can provide
only Stratum 3 timing.
Step 3
Repeat this procedure at each node in the network.
DLP-G95 Set Up External or Line Timing
This task defines the NCS timing source (external or line).
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in
document.
Prerequisite Procedures
Required
Required/As Needed
Onsite or remote
Onsite/Remote
Provisioning or higher
Security Level
Procedure
Step 1
In node view (single-node mode) or shelf view (multishelf mode), click the Provisioning > Timing > General tabs.
Step 2
In the General Timing area, complete the following information:
• Timing Mode-Choose External if the NCS derives its timing from a BITS source wired to the backplane pins (ANSI)
or a MIC-C/T/P front-mount electrical connection (FMEC) (ETSI); choose Line if timing is derived from an OSC-CSM
or OSCM card that is optically connected to the timing node. A third option, Mixed, allows you to set both external
and line timing references. Because Mixed timing might cause timing loops, we do not recommend its use. Use this
mode with care.
In NCS 2006 the BITS is connected to ECU or ECU2 BITS Connectors. Refer to "DLP- L27 Installing
Timing Wires on NCS 2006 - ANSI
" in the Cisco NCS 2002 and NCS 2006 Hardware Installation Guide.
In NCS 2002 he BITS is connected to BITS connectors on the Power Unit.
Note
• SSM Message Set-Choose the Generation 2 synchronization status messaging (SSM) option. See the section
for more information about SSM, including definitions of the SONET
timing levels.
Generation 1 is used only by NCS nodes that are connected to equipment that does not support Generation
2.
Note
6