Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 40
Port 2 (OSC-RX) and Port 3 (COM-TX) of the OPT-BST, OPT-BST-E, or OPT-BST-L cards (or OPT-AMP-L or
OPT-AMP-17-C cards provisioned in OPT-LINE mode).
Step 4
Click Apply.
Step 5
In the confirmation dialog box, click Yes.
Step 6
Return to your originating procedure (NTP).
NTP-G129 Add a DWDM Node
This procedure adds a DWDM node to an existing DWDM
network.
Purpose
None
Tools/Equipment
• "DLP-G46 Log into CTC" task in the "
document.
• Complete the turn up procedures in the “Turn Up a Node”
chapter in the Cisco ONS 15454 DWDM Network
Configuration Guid 
for the node to be added.
• An updated Cisco Transport Planner network plan
recalculated with the new node.
Prerequisite Procedures
As needed
Required/As Needed
Onsite
Onsite/Remote
Provisioning or higher
Security Level
During this procedure, spans will be disconnected in the network at the point where the new node is added.
This is traffic affecting for any unprotected circuits that pass through these spans.
Caution
Procedure
Step 1
If the Cisco Transport Planner network design has not been updated and recalculated for the new node and client services,
update and recalculate it now, using the procedures in the Cisco Transport Planner - DWDM Operations Guide .
Step 2
Complete the “NTP-G51 Verify DWDM Node Turn Up” procedure in the chapter “Turn Up a Network” of the Cisco ONS
15454 DWDM Network Configuration Guide 
for the node to be added. If the node has not been turned up, do not continue.
8