Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 23
• Force-This operation commands the node to switch to the reference you have selected, regardless of the SSM quality
(if the reference is valid).
For information about the Clear option, see the
Timing Reference, on page 14
task.
Note
Step 4
Click Apply next to the timing source.
Step 5
Click Yes in the confirmation dialog box. If the selected timing reference is an acceptable valid reference, the node switches
to the selected timing reference. If the selected timing reference is invalid, a warning dialog box appears. Click OK; the
node will not switch to the new timing reference.
Step 6
Return to your originating procedure (NTP).
DLP-G260 Clear a Manual or Force Switch on a Node Timing Reference
This task clears a Manual or Force switch on a node timing
reference and reverts the timing reference to its provisioned
reference.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Maintenance or higher
Security Level
Procedure
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Timing > Source tabs.
Step 2
Find the Clock reference that is currently set to Manual or Force in the Operation drop-down list.
Step 3
From the Operation drop-down list, choose Clear .
Step 4
Click Apply.
Step 5
Click Yes in the confirmation dialog box. If the normal timing reference is an acceptable valid reference, the node switches
back to the normal timing reference as defined by the system configuration. If the normal timing reference is invalid or
has failed, a warning dialog box appears. Click OK; the timing reference will not revert.
Step 6
Return to your originating procedure (NTP).
14