Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 84
• PPM Type—Choose the number of ports supported by your GBIC, SFP, SFP+, XFP, CXP, or CFP module, from
the drop-down list. The drop-down list displays the number of PPMs that are available for provisioning. If only one
port is supported, PPM (1 port) is the only option.
Step 5
Click OK. The newly created port appears in the Pluggable Port Modules pane. The row in the Pluggable Port Modules
pane turns light blue. The Actual Equipment Type column remains blank until the actual GBIC, SFP, SFP+, XFP, CXP,
or CFP module is installed. After the GBIC, SFP, SFP+, XFP, CXP, or CFP module is installed, the row in the pane turns
white and the Actual Equipment Type column shows the equipment name.
For ONS-SC-EOP1, ONS-SC-EOP3, ONS-SC-E1-T1-PW, ONS-SC-E3-T3-PW, ONS-SC-E1-T1-CES, and
ONS-SC-E3-T3-CES SFPs, set the port rate as FE.
Note
Step 6
Verify that the PPM appears in the list in the Pluggable Port Modules pane. If it does not, repeat
through
Step 7
Repeat
through
to provision a second PPM, if needed. If not, continue with
.
Step 8
Click OK.
Step 9
Return to your originating procedure (NTP).
DLP-G726 Preprovisioning a Multirate PPM
This task provisions a multirate PPM on a line card.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" in the
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Provisioning or higher
Security Level
If the PPM was preprovisioned using the
task, this
task is unnecessary, unless the PPM has an Out-of-Service and Autonomous Management, Unassigned
(ANSI) or Unlocked-disabled, unassigned (ETSI) service state.
Note
Procedure
Step 1
In node view (single-shelf mode) or shelf view (multishelf view), double-click the line card where you want to provision
the multirate PPM settings.
Step 2
If this is the first multirate PPM provisioned for the card, continue with
. If not, complete the following steps.
a) Click the Provisioning Line SONET (ANSI) or SDH (ETSI) tabs.
75