Cisco Cisco NetFlow Generation Appliance (NGA) 3340 Installation Guide

Page of 36
23
Quick Start Guide for Cisco NetFlow Generation Appliance
Quick Start Guide for Cisco NetFlow Generation Appliance (NGA) 3340
  Upgrade and Recovery Procedures
Power Specifications 
 lists the specifications for the power supply.
Upgrade and Recovery Procedures
Cisco occasionally provides upgrades to NGA software you can download and install on your Cisco 
NetFlow Generation Appliance. You might also use the downloadable software to restore your appliance 
software in the case of a catastrophic failure. 
After you upgrade or restore your appliance software, if you have backed up your NGA configuration, 
you can restore that configuration and resume network monitoring without undue delay. 
This section contains the following sections: 
After you complete any changes to your NGA configuration, use the command line interface to 
upload your NGA configuration to an archive server. 
Use the command line interface to restore your previous NGA configuration. 
Download a version of the current NGA software and use a single CLI command to perform the 
software upgrade.
Use the helper utility to perform a recovery installation.
Backing Up Your Configuration
Before you begin the upgrade process, we recommend that you perform a complete backup of your 
current NGA configuration. 
Table 6
Power Supply Specifications
Description
Specification
AC input voltage range
90 to 264 VAC (self-ranging, 100 to 264 VAC nominal)
AC input frequency
Range: 47 to 63 Hz (single phase, 50 to 60Hz nominal)
AC line input current (steady state)
9.5 A peak at 100 VAC
4.5 A peak at 208 VAC
Maximum output power for each power 
supply 
770 W
Power supply output voltage
Main power: 12 VDC
Standby power: 12 VDC