Cisco Cisco Prime Optical 9.8 Developer's Guide

Page of 762
Cisco Prime Optical 9.8 GateWay/CORBA Programmer Reference Guide 
OL-29218-01
 
 
198
 
The default setting for alarmReporting is “on.” If the alarmReporting status is off, it indicates 
that a warning alarm has been raised for it. Prime Optical generates a cleared warning alarm if 
successful. For optical NEs, the interface supports the node names as equipment only when the 
NE alarms are configured with "off." 
Parameters 
Name
 
Type
 
Input/Output
 
Description
 
equipmentOrHolderName
 
Globaldefs::NamingAttributes_T
 
In
 
Equipment on 
which to activate 
alarm reporting.
 
Throws 
Compliance 
TMF-defined. 
3.6.12  unprovisionEquipment 
Synopsis 
Description 
This interface enables the NMS to permanently unprovision equipment from the managed 
element. The successful result of this operation is the potential deletion of the equipment 
object and all of its related objects, such as termination points. 
The ONS 15454 SONET does not allow a user to unprovision a piece of equipment that is in use 
(SNC is created on this equipment). However, if the equipment is present in the slot and is not 
in use, it can be unprovisioned. If the equipment is not physically removed from the slot and 
new equipment is not provisioned in the same slot, the NE redetects the equipment in 
approximately 1 minute. If the equipment is not physically removed from the slot and new 
equipment of a different type is provisioned in the same slot, the NE generates an equipment 
mismatch alarm.