2.1.2.1 Slots
The ONS 15305 and ONS 15305 CTC are single-shelf NEs with four slots.
2.1.2.2 PTPs
The ONS 15305 and ONS 15305 CTC support PTPs associated to WAN, SDH, and PDH ports.
2.1.3 ONS 15310 CL
Prime Optical 9.8 supports.
2.1.3.1 Slots
The ONS 15310 CL is a single-shelf NE with two slots. Slot 1 is the expansion slot and contains
the provisionable data card. Slot 2 is a nonreplicable unit and contains the Control Timing and
Cross-Connect (CTX)-CL controller.
the provisionable data card. Slot 2 is a nonreplicable unit and contains the Control Timing and
Cross-Connect (CTX)-CL controller.
2.1.3.2 Equipment
All cards for the ONS 15310 CL R5.0 and later display administration and service states. For
earlier software releases, these states are not applicable and Prime Optical displays them as
N/A. The following tables show the attribute values for these two states.
earlier software releases, these states are not applicable and Prime Optical displays them as
N/A. The following tables show the attribute values for these two states.
2.1.3.2.1
Equipment Administration State
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in
getAdditionalInfo for the equipment.
getAdditionalInfo for the equipment.
state.
Table 2-1: Equipment Administration State (ONS 15310 CL)
Attribute Value
Meaning
In Service
Places the entity In Service.
Auto in Service
Places the entity in Auto in Service. The circuit is out of service until it
receives a valid signal for the duration of the soak period, at which time
the circuit state changes to In Service. During the soak period, alarms
and loopbacks are suppressed but traffic is carried.
receives a valid signal for the duration of the soak period, at which time
the circuit state changes to In Service. During the soak period, alarms
and loopbacks are suppressed but traffic is carried.
Out of Service–Maintenance
Removes the entity from service for maintenance. Alarms are no longer
generated.
generated.
Out of Service
Removes the entity from service and disables it. Alarms are no longer
generated and traffic is not carried.
generated and traffic is not carried.
2.1.3.2.2
Equipment Service State
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in
getAdditionalInfo for the equipment. The attribute value for the service state is the same as