Cisco Cisco Prime Optical 10.3 Developer's Guide

Page of 688
 
Cisco Prime Optical 10.3 GateWay/CORBA Programmer Reference Guide 
 
 
25
 
2.1.3.8  Autodiscovery 
The ONS 15310 CL supports automatic discovery of connected elements. Prime Optical can 
connect to one node and retrieve information about all connected nodes. The first time Prime 
Optical connects to a node, it retrieves only the IP address of the connected node; Prime Optical 
does not retrieve the node name. However, Prime Optical must report this element to the users. 
Because the IP address is unique, Prime Optical initializes the name of the newly discovered 
element with the IP address. An object creation event is generated for this managed element with 
the IP address as the name. Later, Prime Optical connects to this element and retrieves all 
information, including the actual name, and an attribute value change (AVC) event is generated 
for the managed element name. The NMS listens to the AVC event for the managed element 
name and invokes managedElementManager::ManagedElementManager_I:: 
getManagedElement. 
2.1.4  ONS 15310 MA SDH 
 for the ONS 15310 MA SDH software 
releases that Prime Optical 10.3 supports. 
2.1.4.1  Slots 
The ONS 15310 MA SDH consists of two CTX slots and four Expansion (EXP) I/O slots. 
2.1.4.2  Topological Links 
All topological links are unidirectional or bidirectional for ONS 15310 MASDH NEs. 
2.1.4.3  Cards 
The ONS 15310 MA SDH supports the following cards: 
•  CTX2500 
–  E1_21_E3_DS3_3_LINE_CARD—The electrical ports consist of 21 DS1 and 3 DS3 or EC1 
ports. 
–  E1_63_E3_DS3_3_LINE_CARD—The electrical ports consist of 63 DS1 and 3 DS3 or EC1 
ports. 
•  ML-100T-8 
•  CE-100T-8 
2.1.4.4  PTPs 
All PTPs are bidirectional for the ONS 15310 MA SDH. The ports are always in channelized 
mode. PTPs support In Service and Out of Service–Maintenance values for the service state 
attribute. 
SNC provisioning on E1_21_DS3_3 and E1_63_E3_3 cards uses the following DS3/E3 ports: 
•  E1_21_DS3_3—Port numbers 22, 23, and 24. 
•  E1_63_E3_3—Port numbers 64, 65, and 66. 
2.1.4.5  Auto Discovery 
The ONS 15310 MA SDH supports automatic discovery of connected elements. Prime Optical 
can connect to one node and retrieve information about all connected nodes. The first time Prime 
Optical connects to a node, it retrieves only the IP address of the connected node; Prime Optical 
does not retrieve the node name. However, Prime Optical must report this element to the users. 
Because the IP address is unique, Prime Optical initializes the name of the newly discovered 
element with the IP address. An object creation event is generated for this managed element with