Cisco Cisco Prime Optical 10.3 Developer's Guide
Cisco Prime Optical 10.3 GateWay/CORBA Programmer Reference Guide
27
managed element name. The NMS listens to the AVC event for the managed element name and
invokes managedElementManager::ManagedElementManager_I:: getManagedElement.
invokes managedElementManager::ManagedElementManager_I:: getManagedElement.
2.1.6 ONS 15327
See the
for the ONS 15327 software releases that
Prime Optical 10.3 supports.
2.1.6.1 Slots
The ONS 15327 is a single-shelf NE with eight slots. The Mechanical Interface Card (MIC) A
card must occupy slot 8; the MIC B card must occupy slot 7. If an integrated Cross-Connect,
Timing, and Control (XTC) card is required, it must occupy slot 5 or slot 6.
card must occupy slot 8; the MIC B card must occupy slot 7. If an integrated Cross-Connect,
Timing, and Control (XTC) card is required, it must occupy slot 5 or slot 6.
2.1.6.2 Equipment
All of the cards in the ONS 15327 R5.0 and later display administration and service states. For
earlier software releases, these states are not applicable and Prime Optical displays them as N/A.
earlier software releases, these states are not applicable and Prime Optical displays them as N/A.
2.1.6.2.1
Equipment Administration State
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in
getAdditionalInfo for the equipment. Table 2-4 lists the attribute values for the administration
state. Table 2-5 and Table 2-6
getAdditionalInfo for the equipment. Table 2-4 lists the attribute values for the administration
state. Table 2-5 and Table 2-6
list the attribute values for the service state.
Table 2-4: Equipment Administration State (ONS 15327)
Attribute Value
Meaning
In Service
Places the entity In Service.
Auto in Service
Places the entity in Auto in Service. The circuit is out of service until it
receives a valid signal for the duration of the soak period, at which
time the circuit state changes to In Service. During the soak period,
alarms and loopbacks are suppressed but traffic is carried.
receives a valid signal for the duration of the soak period, at which
time the circuit state changes to In Service. During the soak period,
alarms and loopbacks are suppressed but traffic is carried.
Out of Service–Maintenance
Removes the entity from service for maintenance. Alarms are no
longer generated.
longer generated.
Out of Service
Removes the entity from service and disables it. Alarms are no longer
generated and traffic is not carried.
generated and traffic is not carried.
2.1.6.2.2
Equipment Service State
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in
getAdditionalInfo for the equipment. The attribute value for the service state is the same as that
shown in Prime Optical.
getAdditionalInfo for the equipment. The attribute value for the service state is the same as that
shown in Prime Optical.
Table 2-5: Equipment Service State–Primary (ONS 15327)
Primary States (PST-PSTQ)
Attribute Value
Meaning
In Service–Normal (IS_NR)
The entity is fully operational and performs as provisioned.
Out of Service–Management
(OOS_MA)
(OOS_MA)
The entity has been administratively removed from service.
Out of Service–Autonomous
(OOS_AU)
(OOS_AU)