Cisco 1 GHz Surge-Gap Reverse Window Taps Installation Guide

Page of 74
 
 
Installing the Tap Housing in a Pedestal 
4013399 Rev C 
25 
 
Installing the Tap Housing in a Pedestal 
The pedestal-mounted configuration has the feeder cable entering and exiting the 
unit from the bottom. The tap without traps or filters fits in a 6-in. round or square 
pedestal. A larger pedestal is needed if traps or filters are installed. 
 
To Install the Tap Housing in a Pedestal 
Follow these steps to install a tap housing in a pedestal. 
1  Begin this procedure with the faceplate removed. Refer to To Remove the 
Faceplate (on page 20). 
2  Using a 3/8-in. wrench, remove the strand bolt and strand clamp from the 
housing. 
3  Mount the housing to the pedestal-mounting bracket using the strand bolt. Use 
the strand clamp as a spacer, if necessary. 
 
4  Using a 3/8-in. wrench, tighten the strand bolt from 30 in-lb to 40 in-lb (3.4 Nm 
to 4.5 Nm).