Cisco 1 GHz Surge-Gap Reverse Window Taps Installation Guide

Page of 74
 
 
Mounting the Faceplate 
4013399 Rev C 
27 
 
Mounting the Faceplate 
After mounting the housing and connecting the feeder cables, you are ready to 
install the faceplate in the tap housing. 
 
To Mount the Faceplate 
Follow these steps to attach the faceplate to the housing. 
1  If the housing is installed on a strand, go to step 2. 
If the housing is installed in a pedestal, go to step 3. 
  
WARNING: 
Protect yourself from electric shock and your equipment from damage. 
Certain components can deliver an electrical shock.
 
2  Attach a grounding wire assembly to the strand wire and a drop port F-
connector. 
 
Proceed to step 4. 
3  Attach a grounding wire assembly to the strand clamp bolt on the pedestal and a 
drop port F-connector.