Cisco Flexible Solutions Taps Installation Guide

Page of 74
 
 
Removing the Faceplate 
4013399 Rev C 
21 
 
To Remove a Faceplate with Feeder Cables Connected (Hot Install) 
Follow these steps to remove a faceplate with feeder cables already connected to the 
housing. 
1  Remove all coax drop cables from the drop port F-connectors. 
2  Using a 3/8-in. wrench, loosen all faceplate bolts. 
3  If the housing is installed on a strand, go to step 4. 
If the housing is installed on a pedestal, go to step 5. 
  
WARNING: 
Protect yourself from electric shock and your equipment from damage. 
Certain components can deliver an electrical shock.
 
4  Attach a grounding wire assembly to the strand wire and a drop port F-
connector. 
 
Proceed to step 6. 
5  Attach a grounding wire assembly to the strand clamp bolt on the pedestal and a 
drop port F-connector.