Chapter 2    Installing the Tap 
 
 
 
20 
4014133 Rev D 
5  Using a 3/16-in. hex-head driver or 3/16-in. straight blade screwdriver, loosen 
the two seizure screws inside the housing. 
 
6  Thread the prepared KS-connectors into the housing at the cable side entry port 
locations as shown in the figure above.  Make sure to tighten the connector 
according to the manufacturer’s recommended torque specification, typically 15 
ft-lb to 25 ft-lb (20.3 Nm to 33.9 Nm), but not to exceed 60 ft-lb (81.3 Nm). 
7  Using a 3/16-in. hex-head driver or 3/16-in. straight blade screwdriver, tighten 
the two seizure screws from 15 in-lb to 20 in-lb (1.7 Nm to 2.3 Nm). See the 
diagram in step 5 for the location of the two seizure screws. 
8  Replace the end plugs on the unused entry ports and torque with a 3/8-in. hex 
wrench from 50 in-lb to 60 in-lb (5.6 Nm to 6.8 Nm). 
9  Attach the faceplate to the housing. Refer to To Mount the Faceplate (on page 
23). 
10  Attach the drop cable (RG-6 or RG-59) to the tap faceplate. 
 
Note:  Be sure to provide strain relief for the coax drop cable per manufacturer’s 
recommendation, and terminate all unused F-ports with 75 
 terminators.