Cisco Flexible Solutions Taps Installation Guide

Page of 48
 
Chapter 2        Installing the Tap 
 
 
 
18 
 
5  Using a 3/16-in. hex-head driver or 3/16-in. straight blade screwdriver, loosen 
the two seizure screws inside the housing. 
 
6  Thread the prepared KS-connectors into the cable side entry port as shown in the 
figure above. Make sure to tighten the connector according to the manufacturer’s 
recommended torque specification, typically 15 ft-lb to 25 ft-lb (20.3 Nm to 33.9 
Nm), but not to exceed 60 ft-lb (81.3 Nm). 
7  Using a 3/16-in. hex-head driver or 3/16-in. straight blade screwdriver, tighten 
the two seizure screws from 15 in-lb to 20 in-lb (1.7 Nm to 2.3 Nm). See the 
diagram in step 5 for the location of the two seizure screws. 
8  Replace the end plugs on the unused entry ports and torque with a 3/8-in. hex 
wrench from 50 in-lb to 60 in-lb (5.6 Nm to 6.8 Nm). 
9  Attach the faceplate to the housing. Refer to To Mount the Faceplate (on page 
21). 
10  Attach the drop cable (RG-6 or RG-59) to the tap faceplate. 
 
Note:    Be sure to provide strain relief for the coax drop cable per manufacturer’s 
recommendation, and terminate all unused F-ports with 75
terminators.